Max. DC Voltage: 1000V
Input/Output Strings: 16-in / 1-out
Max. Input Current (per string): 25A
Max. Output Current: 400A
Surge Protection: Type 2, 40kA
DC Fuse: 10x38mm, 15A
DC Protection Switch: DC MCCB, 1000V/400A
Enclosure: Metal, IP65, IK10
The EKDBT-PV16/1-BFS-1000 is engineered for the largest solar PV projects, offering 16 string inputs within a highly durable IP65/IK10 metal enclosure. This unit features a 400A DC MCCB, providing robust protection and efficient power aggregation for utility-scale and extensive commercial solar arrays.
Applications:
This 16-string combiner box is the solution for large-scale solar power generation, including utility solar farms, extensive industrial rooftops, and ground-mount commercial projects where maximum string density and robust protection are critical.
|
Model |
EKDBT-PV16/1-FBS-1000 |
|
Number of input strings |
16 |
|
Number of output strings |
1 |
|
Max. DC voltage |
1000V |
|
Max. input current per string |
25A |
|
Max. output current |
400A |
|
Surge Protection |
|
|
Type |
Type 2 (optional: Type1+2) |
|
Max. operation voltage (Ucpv) |
1000V |
|
Max. discharge current (Imax) |
40kA |
|
Voltage protection level |
4kV |
|
Poles |
2 |
|
Design features |
Plug-in module |
|
Standard |
IEC/EN 61643-31 |
|
DC Fuse |
|
|
Rated operation voltage(Ue) |
1000V |
|
Rated current (Ie)(Changeable) |
15A |
|
Type of fuses |
10x38mm,30kA |
|
Standard |
IEC 60947-3 & IEC 60269-6 |
|
DC Protection Switch |
DC MCCB |
|
Rated insulation voltage (Ui) |
1500V |
|
Rated operating voltage (Ue) |
1000V |
|
Rated current(In) |
400A |
|
Poles |
2P |
|
Rated short-circuit breaking capacity (Ics/Icu) |
15kA/15kA @1000VDC |
|
Standard |
IEC/EN 60947-2 |
|
Others |
|
|
Anti reflection diode |
Optional |
|
String monitoring module |
Optional(50~1500V,0~20A,RS485/ModBus-RTU) |
|
Enclosure |
|
|
Enclosure type |
Metal(Other shell materials can be customized) |
|
Degree of Protection |
IP65 |
|
Impact protection level |
IK10 |
|
Enclosure size |
860x560x200mm |
|
Input or output connector |
Waterproof gland (default), MC4 connector (optional) |
|
Environment |
|
|
Operating Temperature |
-25℃ to +55℃ |
|
Cooling way |
Natural cooling |
|
Humidity |
0~95% |
|
Altitude |
2000m |
|
Installation |
Wall Mounting |
GET A QUOTE